NATIONAL STANDARD TCVN 5699-2-15 : 2013 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-15: SPECIFIC REQUIREMENTS FOR HEATING LIQUIDS
This standard deals with the safety of electrical appliances for household and similar purposes having a rated voltage not exceeding 250V
Appliances intended for household and similar use and which may also be used by laymen in shops, in light industry and on farms are also within the scope of this standard.
Standard TCVN 5699-2-15 issued on the contents is regulated as follows:
1 Scope
2 Normative references
3 Terms and definitions
4 General requirement
5 General conditions for the tests
6 Classification
7 Marking and instructions
8 Protection against access to live parts
9 Starting of motor-operated appliances
10 Power input and current
11 Heating
12 Void
13 Leakage current and electric strength at operating temperature
14 Transient overvoltages
15 Moisture resistance
16 Leakage current and electric strength
17 Overload protection of transformers and associated circuits
18 Endurance
19 Abnormal operation
20 Stability and mechanical hazards
21 Mechanical strength
22 Construction
23 Internal wiring
24 Components
25 Supply connection and external flexible cords
26 Terminals for external conductors
27 Provision for earthing
28 Screws and connections
29 Clearances, creepage distances and solid insulation
30 Resistance to heat and fire
31 Resistance to rusting
32 Radiation, toxicity and similar hazards
In addition to the main contents above, the standard also has the following appendices:
Annex A (informative) Routine tests
Annex B (normative) Appliances powered by rechargeable batteries
Annex C (normative) Ageing test on motors
Annex D (normative) Thermal motor protectors
Annex E (normative) Needle-flame test
Annex F (normative) Capacitors
Annex G (normative) Safety isolating transformers
Annex H (normative) Switches
Annex I (normative) Motors having basic insulation that is inadequate for the rated voltage of the appliance
Annex J (normative) Coated printed circuit boards
Annex K (normative) Overvoltage categories
Annex L (informative) Guidance for the measurement of clearances and creepage distances
Annex M (normative) Pollution degree
Annex N (normative) Proof tracking test
Annex O (informative) Selection and sequence of the tests of Clause 30
Annex P (informative) Guidance for the application of this standard to appliances used in warm damp equable climates
Annex Q (informative) Sequence of tests for the evaluation of electronic circuits
Annex R (normative) Software evaluation
We can also perform testing on standard versions of the following countries:
TCVN 5699-2-15:2013
IEC 60335-2-15:2000,IEC 60335-2-15:2002+ A1:2005+A2:2008
IEC 60335-2-15:2012
IEC 60335-2-15:2012 + AMD1:2016 + AMD2: 2018
EN 60335-2-15:2002+ A1:2005+A2:2008+A11:2012+AC:2013
EN 60335-2-15:2016 + A11:2018
KC 60335-2-15:2008
KC 60335-2-15:2015
KC 60335-2-15:2020
KC 60335-2-15:2022
GB4706.19-2008 JIS C 9335-2-15:2004
CSA C22.2 No. 60335-2-15
TIS 1039 -2547
TIS 2062 -2558
TIS 2439 – 2559
CNS 60335-2-15
IS 302-2-15:2009
GSO IEC 60335-2-15:2009
RTE INEN 227:2016
SANS 60335-2-15:2018
PE Nº1/12:2021
With:
IEC – The International Electrotechnical Commission
EN – Europe
KC – Korea
GB – China
CSA – Canada
TIS – Thailand
CNS – Taiwan
IS - India
GSO – Gulf
RTE INEN – Ecuador
SANS – South Africa
PE – Chile
Contact information for consultation: GCL CO., LTD (HCM)
Hotline: 0393423091 | Hanoi: 02473099929
Email: hcm@gclab.org | louise.vietnam@pcn-global.com
Office: No. 27, Street 12, Khang Dien Residential Area, Phuoc Long B Ward, Thu Duc City, Ho Chi Minh City
Testing room: No. 115, An Phu 04 Alley, An Phu Ward, Thuan An City, Binh Duong Province.
1 Scope
2 Normative references
3 Terms and definitions
4 General requirement
5 General conditions for the tests
6 Classification
7 Marking and instructions
8 Protection against access to live parts
9 Starting of motor-operated appliances
10 Power input and current
11 Heating
12 Void
13 Leakage current and electric strength at operating temperature
14 Transient overvoltages
15 Moisture resistance
16 Leakage current and electric strength
17 Overload protection of transformers and associated circuits
18 Endurance
19 Abnormal operation
20 Stability and mechanical hazards
21 Mechanical strength
22 Construction
23 Internal wiring
24 Components
25 Supply connection and external flexible cords
26 Terminals for external conductors
27 Provision for earthing
28 Screws and connections
29 Clearances, creepage distances and solid insulation
30 Resistance to heat and fire
31 Resistance to rusting
32 Radiation, toxicity and similar hazards
In addition to the main contents above, the standard also has the following appendices:
Annex A (informative) Routine tests
Annex B (normative) Appliances powered by rechargeable batteries
Annex C (normative) Ageing test on motors
Annex D (normative) Thermal motor protectors
Annex E (normative) Needle-flame test
Annex F (normative) Capacitors
Annex G (normative) Safety isolating transformers
Annex H (normative) Switches
Annex I (normative) Motors having basic insulation that is inadequate for the rated voltage of the appliance
Annex J (normative) Coated printed circuit boards
Annex K (normative) Overvoltage categories
Annex L (informative) Guidance for the measurement of clearances and creepage distances
Annex M (normative) Pollution degree
Annex N (normative) Proof tracking test
Annex O (informative) Selection and sequence of the tests of Clause 30
Annex P (informative) Guidance for the application of this standard to appliances used in warm damp equable climates
Annex Q (informative) Sequence of tests for the evaluation of electronic circuits
Annex R (normative) Software evaluation
We can also perform testing on standard versions of the following countries:
TCVN 5699-2-15:2013
IEC 60335-2-15:2000,IEC 60335-2-15:2002+ A1:2005+A2:2008
IEC 60335-2-15:2012
IEC 60335-2-15:2012 + AMD1:2016 + AMD2: 2018
EN 60335-2-15:2002+ A1:2005+A2:2008+A11:2012+AC:2013
EN 60335-2-15:2016 + A11:2018
KC 60335-2-15:2008
KC 60335-2-15:2015
KC 60335-2-15:2020
KC 60335-2-15:2022
GB4706.19-2008 JIS C 9335-2-15:2004
CSA C22.2 No. 60335-2-15
TIS 1039 -2547
TIS 2062 -2558
TIS 2439 – 2559
CNS 60335-2-15
IS 302-2-15:2009
GSO IEC 60335-2-15:2009
RTE INEN 227:2016
SANS 60335-2-15:2018
PE Nº1/12:2021
With:
IEC – The International Electrotechnical Commission
EN – Europe
KC – Korea
GB – China
CSA – Canada
TIS – Thailand
CNS – Taiwan
IS - India
GSO – Gulf
RTE INEN – Ecuador
SANS – South Africa
PE – Chile
Contact information for consultation: GCL CO., LTD (HCM)
Hotline: 0393423091 | Hanoi: 02473099929
Email: hcm@gclab.org | louise.vietnam@pcn-global.com
Office: No. 27, Street 12, Khang Dien Residential Area, Phuoc Long B Ward, Thu Duc City, Ho Chi Minh City
Testing room: No. 115, An Phu 04 Alley, An Phu Ward, Thuan An City, Binh Duong Province.